Pengaruh Radiasi Neutron Terhadap Waktu Relaksasi Spin-Kisi (T1) Pada Polimer Polivinil Klorida (Pvc) dengan Spektroskopi Nmr Pulsa

Authors

Susilawati Susilawati

DOI:

10.29303/jpft.v1i1.237

Published:

2017-03-14

Issue:

Vol. 1 No. 1 (2015): Januari

Keywords:

neutron radiation, relaxation time, the polymer PVC

Articles

Downloads

How to Cite

Susilawati, S. (2017). Pengaruh Radiasi Neutron Terhadap Waktu Relaksasi Spin-Kisi (T1) Pada Polimer Polivinil Klorida (Pvc) dengan Spektroskopi Nmr Pulsa. Jurnal Pendidikan Fisika Dan Teknologi, 1(1), 67–76. https://doi.org/10.29303/jpft.v1i1.237

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

Abstract

A research measurement of spin-lattice relaxation time (T1) with a pulse NMR spectrometer as well as a test of strength (tensile test and compression test) polymer material PVC (Poly Vinyl Chloride) with tools united-1 test system SFM SFM-30. The study aims to investigate the influence of the neutron fluence on the spin-lattice relaxation time (T1) and to determine the PVC polymer material strength test. On the measurement of the spin-lattice relaxation time (T1) is used method pulse 180o-t-90o and pulse method 90o-t-90o, by means of NMR minispec P.20. Measurement of PVC polymer material strength testing using tools united-1 test system SFM SFM-30. The results showed that the spin-lattice relaxation time (T1) PVC polymer influenced by variations in relaxation times (fluence) neutrons. From the graph of the spin-lattice relaxation time (T1) vs. neutron fluence with the method 90o-t-90o obtained increases and decreases in the value of T1. The value of the spin-lattice relaxation time at the minimum fluence 34.56x1016n/cm2, and the average value of the minimum T1 is (271.1̱5.4) for the milli second pulse method 180o-t-90o and the average value The minimum T1 is (263.5̱5.3) for the milli second pulse method 90o-t-90o. The value of the spin-lattice relaxation time at the maximum fluence 60.98 x 1016 n/cm2, the average value of the minimum T1 was (481.9̱10.1) milli second to the method also 180o-t-90o and the average value of T1 The minimum was (482.5̱9.7) for the milli second pulse method 90o-t-90o. Test the strength of the PVC polymer is affected by the neutron fluence. Graph PVC polymer material strength test vs. neutron fluence obtained increases and decreases in the value of the strength of the PVC polymer. Value of the minimum strength of the PVC polymer materials at fluence 34.56 x 1016 n/cm2, the average value of the minimum ̮ is (9.5̱ 0.1) MPa for tensile test, and the average value is the minimum ̮ (38.4̱0.1) MPa for compression test. Value of the maximum power of the PVC polymer materials at fluence 60.98x1016n/cm2, the average value of the maximum ̮ is (43.2̱0.9) MPa for tensile test and the average value of the maximum ̮ is (55.4̱1.1) MPa for compression test.

License

Authors who publish with Jurnal Pendidikan Fisika dan Teknologi (JPFT) agree to the following terms:

  1. Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License 4.0 International License (CC-BY-SA License). This license allows authors to use all articles, data sets, graphics, and appendices in data mining applications, search engines, web sites, blogs, and other platforms by providing an appropriate reference. The journal allows the author(s) to hold the copyright without restrictions and will retain publishing rights without restrictions.
  2. Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in Jurnal Pendidikan Fisika dan Teknologi (JPFT).
  3. Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).

Most read articles by the same author(s)

1 2 > >> 

Similar Articles

<< < 1 2 3 

You may also start an advanced similarity search for this article.