A Case Study of the Head CT Scan Procedure in Pediatric Patients with Clinical Hydrocephalus at Hospital X Ponorogo
Authors
Hanifa Larasati Dewi , Ildsa Maulidya Mar’athus Nasokha , Asih Puji UtamiDOI:
10.29303/jbt.v25i4.10197Published:
2025-10-01Issue:
Vol. 25 No. 4 (2025): Oktober-DesemberKeywords:
Head CT scan, hydrocephalus, pediatric, radiation protection, protocol.Articles
Downloads
How to Cite
Downloads
Metrics
Abstract
Hydrocephalus is a common congenital abnormality in pediatric patients, characterized by ventricular enlargement due to the accumulation of cerebrospinal fluid (CSF). However, variations in handling, parameters, and radiation protection exist among hospitals, necessitating further evaluation. This study aims to analyze the head CT scan procedure in pediatric patients with clinical hydrocephalus. This study employed qualitative case study design involving a 7-month-old pediatric patient with an indication of hydrocephalus. Data were obtained through observation and interviews with three radiographers and one radiology specialist, as well as from secondary sources. The hospital’s examination procedure included general preparation, positioning the patient supine (head first), and no sedation was performed. Technical parameters used the default settings of the machine, 120 kV, 140 mAs, slice thickness of 5 mm, and reconstruction slice of 1.25 mm, for both pediatric and adult patients. Radiation protection was applied only to the patient’s companion, while the patient dose was monitored by the CT system. Radiographic findings indicated obstructive hydrocephalus with a cystic lesion, with the underlying cause identified as Dandy–Walker malformation. In conclusion, pediatric head CT scan procedures were performed according to basic standards. However, the use of standard parameters and limited radiation protection indicate a need for improvement. It is recommended to implement protocols tailored to the patient's age and clinical condition, and optimize radiation protection according to the ALARA principle, to improve examination quality and patient safety.
References
Al Amin, M. (2017). Klasifikasi kelompok umur manusia berdasarkan analisis dimensifraktal box counting dari citra wajah dengan deteksi tepi canny. MATHunesa: Jurnal Ilmiah Matematika, 5(2). https://ejournal.unesa.ac.id/index.php/mathunesa/article/view/19398
Alatas, Z. (2017, October). Risiko Radiasi Dari Computed Tomography Pada Anak. In Jurnal Forum Nuklir (Vol. 8, No. 2, pp. 181-189).
Arlachov, Y., & Ganatra, R. H. (2012). Sedation/anaesthesia in paediatric radiology. The British journal of radiology, 85(1019), e1018-e1031. 10.1259/bjr/28871143
Badan Pengawas Tenaga Nuklir (BAPETEN). (2013). Peraturan Kepala Badan Pengawas Tenaga Nuklir Nomor 4 Tahun 2022 tentang Keselamatan Radiasi pada Penggunaan Pesawat Sinar x dalam radiologi diagnostic dan intervensional.
Bontrager, K. L., & Lampignano, J. P. (2018). Textbook of Radiographic Positioning and Related Anatomy. Elsevier.
Dari, D. W., Wulandari, P. I., & Kusman, K. (2023). Evaluasi Implementasi Proteksi Radiasi Di Ruang Radiologi Intervensi Instalasi Rir Rsup Prof. Dr. Igng Ngoerah. Humantech: Jurnal Ilmiah Multidisiplin Indonesia, 2(3), 604-619. https://journal.ikopin.ac.id/index.php/humantech/article/view/2942
Ghannam, J. Y., & Al Kharazi, K. A. (2023). Neuroanatomy, cranial meninges. In StatPearls [Internet]. StatPearls Publishing.
Grey, M. L., & Ailnami, J. M. (2018). CT & MRI Pathology: A Pocket Atlas.
Hilmiyati, Rafika & Angella, Shelly. (2024). Penatalaksanaan CT-Scan Kepala dengan Klinis Trauma Ringan di Unir Radiologi X Pekanbaru. Jurnal Penelitian Ilmiah Multidisiplin, 8 (1): 370-376. https://sejurnal.com/pub/index.php/jpim/article/view/549
Ibad, Z. N., Muslim, M., & Sofyan, H. (2021). Perbandingan dosis permukaan pada pemeriksaan thorax anak menggunakan metode automatic exposure control dan metode manual. Jurnal Sains dan Teknologi Nuklir Indonesia (Indonesian Journal of Nuclear Science and Technology), 21(2), 61-71. 10.17146/jstni.2020.21.2.5754
Indrati, R., Masrochah, S., Susanto, E., Kartikasari, Y., Wibowo, A. S., Darmini, A. B., & Rasyid, M. E. (2017). Proteksi radiasi bidang radiodiagnostik dan intervensional. Magelang: Inti Medika Pustaka.
Irsal, M., & Winarno, G. (2020). Pengaruh Parameter Milliampere-Second (mAs) terhadap Kualitas Citra Dan Dosis Radiasi Pada Pemeriksaan CT scan Kepala Pediatrik. Jurnal Fisika Flux: Jurnal Ilmiah Fisika FMIPA Universitas Lambung Mangkurat, 17(1), 1-8. https://ppjp.ulm.ac.id/journal/index.php/f/article/view/7085/0
Isaacs, A. M., Riva-Cambrin, J., Yavin, D., Hockley, A., Pringsheim, T. M., Jette, N., ... & Hamilton, M. G. (2018). Age-specific global epidemiology of hydrocephalus: systematic review, metanalysis and global birth surveillance. PloS one, 13(10), e0204926. 10.1371/journal.pone.0204926
Kartawiguna, D., dkk. (2017). Instrumental Pemindai Tomografi Komputer (CT-Scan). Yogyakarta: Pustaka Panasea.
Kementerian Kesehatan Republik Indonesia. (2014). Peraturan Menteri Kesehatan Republik Indonesia Nomor 25 Tahun 2014 tentang Upaya Kesehatan Anak.
Koleva, M., & Jesus, O. D. (2023). Hydrocephalus. In StatPearls. StatPearls Publishing.
Latifah, R., Jannah, N. Z., & Nurdin, D. Z. (2019). Determination Of Local Diagnostic Reference Level (Ldl) Pediatric Patients On Ct Head Examination Based On Size-Specific Dose Estimates (Ssde) Values. Journal of Vocational Health Studies, 2(3), 127-133. https://doi.org/10.20473/jvhs.V2.I3.2019.127-133
Long, B. W., Rollins, J. H., & Smith, B. J. (2016). Merrill’s Atla s of Radiographic Positioning & Procedures (13th ed.). Missouri: Elsevier Mosby.
Mahmudah, D., Sokhibi, A. H., & Hafifudin, R. (2024). Meningkatkan Kepatuhan terhadap Protokol Keselamatan Radiasi: Dampak Pelatihan dan Teknologi Canggih. Journal of Nursing and Health Science, 3(2), 46-53. https://e-journalstikes-pertamedika.ac.id/jnhs/article/view/166
Park, K. S. (2023). Nervous system. In Humans and electricity: Understanding body electricity and applications (pp. 27-51). Cham: Springer International Publishing.
Sari, A. W., Putri, M. N., & Musrifah, F. (2022). Pengukuran Dosis Radiasi Organ Tyroid Keluarga Pasien Pada Pemeriksaan Ct Scan Kepala Pediatrik. Medical Imaging and Radiation Protection Research (MIROR) Journal, 2(2), 41-46. 10.54973/miror.v2i2.254
Sarjani, N. N. (2022). Teknik Pemeriksaan Ct-Scan Kepala Kontras Kasus Cephalgia Di Instalasi Radiologi Rsud Karangasem. MIDWINERSLION: Jurnal Kesehatan STIKes Buleleng, 7(2), 26-30. https://doi.org/10.52073/midwinerslion.v7i2.266
Seeram, E. (2016). Computed Tomography: Physical Principles, Clinical Applications (4th ed.). Elsevier.
Seeram, E. (2022). Computed Tomography - E-Book: Computed Tomography - E-Book. Saunders.
Soediono, B. (2014). INFO DATIN KEMENKES RI Kondisi Pencapaian Program Kesehatan Anak Indonesia. Journal of Chemical Information and Modeling, 53, 160.
Tamber, M. S. (2021). Insights into the epidemiology of infant hydrocephalus. Child's Nervous System, 37(11), 3305-3311. 10.1007/s00381-021-05157-0
Thut, D. P., Kreychman, A., & Obando, J. A. (2014). 111In-DTPA cisternography with SPECT/CT for the evaluation of normal pressure hydrocephalus. Journal of Nuclear Medicine Technology, 42(1), 70-74. 10.2967/jnmt.113.128041
Utami, A. P., Andriani, I., & Budiwati, T. (2018). Prosedur Pemeriksaan CT Scan Kepala Pada Kasus Cerebrovascular Accident (CVA) Bleeding di Instalasi Radiologi Rumah Sakit TK. II 04.05. 01 Dr. Soedjono Magelang. Jurnal Ilmu dan Teknologi Kesehatan, 4(2). https://doi.org/10.33666/jitk.v4i2.88
Wijokongko, S., Ardiyanto, J., Fatimah, Utami, A. P., & Rustanto. (2016). Protokol Radiologi CT Scan dan MRI (Jilid 2). Magelang: Inti Medika Pustaka.
World Health Organization. (n.d.). Computed Tomography in Children.
License
Copyright (c) 2025 Hanifa Larasati Dewi, Ildsa Maulidya Mar’athus Nasokha, Asih Puji Utami

This work is licensed under a Creative Commons Attribution 4.0 International License.
Jurnal Biologi Tropis is licensed under a Creative Commons Attribution 4.0 International License.
The copyright of the received article shall be assigned to the author as the owner of the paper. The intended copyright includes the right to publish the article in various forms (including reprints). The journal maintains the publishing rights to the published articles.
Authors are permitted to disseminate published articles by sharing the link/DOI of the article at the journal. Authors are allowed to use their articles for any legal purposes deemed necessary without written permission from the journal with an acknowledgment of initial publication to this journal.