Microbiological Analysis of Escherichia coli in Refilled Drinking Water in Pariaman City

Authors

Muthii’ah Zahra , Elsa Yuniarti , Fitria Fitria

DOI:

10.29303/jbt.v26i4.12397

Published:

2026-11-14

Downloads

Abstract

Drinking water is the most important substance in life after water. Drinking water containing Escherichia coli bacteria indicates that the water is still polluted. The purpose of this study was to determine the quality of drinking water and identify the presence of bacteria from and E. coli in drinking water samples. The method used in this study was a membrane filter using 4 drinking water samples. From the results of testing drinking water depot samples, it showed that the S.030a sample obtained E. Coli results of 13 CFU / ml, the S.031a sample obtained 1 CFU / ml, the S.032a sample obtained 0 CFU / ml and the S. 036a sample obtained 0 CFU / ml. From the drinking water examined, there were 2 samples that did not meet drinking water quality standards and there were 2 samples that met drinking water quality standards. In accordance with the Minister of Health Regulation 2 of 2023 concerning Environmental Health, the drinking water quality standard is 0 CFU / 100 ml.

Keywords:

Drinking Water Escherichia coli Membrane Filter

References

Apriani, D., Munawar, K., & Setiawan, A. (2019). Alat Monitoring pada Depo Air Minum Biru Cabang Nagrak Kota Tangerang Menggunakan Air Galon Berbasis SMS Gateway. SENSI Journal, 5(1), 109 117.https://www.neliti.com/publications/318159/alat-monitoring-pada-depo-air-minum-biru-cabang-nagrak-kota-tangerang menggunakan

Ariani, M., Yuniarti, E., & Erlinda. (2025). Pemeriksaan sampel air minum dengan metode Most Probable Number (MPN) di Laboratorium Kesehatan Provinsi Sumatera Barat. Prosiding Seminar Nasional Biologi, 4(2).https://doi.org/10.24036/prosemnasbio/vol4/984

Aulia, A. M., & Yuniarti, E. (2025). Pemeriksaan kualitas air minum menggunakan metode CFU untuk menentukan kandungan Coliform dan E. coli di UPTD Laboratorium Kesehatan Provinsi Sumatera Barat. Prosiding Seminar Nasional Biologi, 5(1), 636–643. https://doi.org/10.24036/prosemnasbio/vol5/1208

Azkhiyati, N. (2023). Analisis kualitas mikrobiologi air minum pada depot air minum isi ulang (DAMIU). Jurnal Ilmu Kesehatan Masyarakat, 12(1), 45–58. http://ejournal.fkm.unsri.ac.id/index.php/jikm

Bandu, A., Tuju, T. D. J., & Assa, J. R. (2023). Analisis kualitas bakteriologis (E. coli dan coliform) air minum isi ulang (AMIU) di Kecamatan Lolak Kabupaten Bolaang Mongondow. Jurnal Teknologi Pertanian (Agricultural Technology Journal), 14(1), 32–42. https://doi.org/10.35791/jteta.v14i1.50694

Fadila, S. I., Yuniarti, E., & Yumna, H. (2024). Uji bakteri Escherichia coli dan Coliform dengan metode MPM (Most Probable Number) pada uji kualitas air minum. Prosiding Seminar Nasional Biologi, 3(2), 725-731. https://doi.org/10.24036/prosemnasbio/vol3/774

Fajar, M. M., Kurniawan, M. R., & Wijayanti, D. R. (2023). Kontaminasi Escherichia coli pada air minum isi ulang di wilayah Ciangsana menggunakan uji Most Probable Number (MPN). Borneo Journal of Medical Laboratory Technology, 5(2), 278–282. https://doi.org/10.33084/bjmlt.v5i2.4102

Febria, F. A. (2022). Uji bakteriologis sumber air masyarakat Kota Pariaman. Jurnal Biologi Universitas Andalas, 10(1), 15–22. http://jba.fmipa.unand.ac.id/index.php/jba/article/view/354

Hardianto, T., dkk. (2022). Analisis Mikrobiologi Air dengan Metode Filtrasi Membran. Jurnal Teknologi Lingkungan. https://ejournal.undip.ac.id/index.php/jtli

Harianja, E. S., Sipayung, A. D., Purba, S. D., & Abdilla, T. I. (2022). Pemeliharaan peralatan dan pengawasan pengolahan depot air minum isi ulang dengan kontaminasi Escherichia coli pada air minum. Sanitasi: Jurnal Kesehatan Lingkungan, 15(2), 88–96. https://doi.org/10.29238/sanitasi.v15i2.1367

Julianti, R. N. D., & Pawenang, E. T. (2025). Hubungan higiene sanitasi dengan keberadaan Escherichia coli pada depot air minum di wilayah pengawasan Dinas Kesehatan Kabupaten Rembang tahun 2023. Jurnal Penelitian dan Pengembangan Kesehatan Masyarakat Indonesia, 5(1). https://journal.unnes.ac.id/journals/jppkmi/article/view/8911

Munfiah, S. (2013). Kualitas fisik dan mikrobiologi air sumur gali di Desa Gudo Kecamatan Gudo Kabupaten Jombang. Jurnal Kesehatan Lingkungan, 7(1), 1–9. https://journal.unair.ac.id/index.php/JKL

Narsi, Wahyuni, R. R., & Susanti, Y. (2017). Uji Kelayakan Air Minum Isi Ulang Di Pasir Pengaraian Kabupaten Rokan Hulu Riau. Jurnal Ilmu Pangan dan Hasil Pertanian, 1(1), 11–21. http://journal.upgris.ac.id/index.php/JIPHP/article/view/1553

Nugraha, A. (2019). Hubungan Higiene Sanitasi dengan Kualitas Mikrobiologi Air Minum Isi Ulang (DAMIU). Jurnal Kesehatan Masyarakat. https://ejournal3.undip.ac.id/index.php/jkm/article/view/24376

Pratama, R. (2020). Analisis Parameter Fisik dan Mikrobiologi pada Depot Air Minum Isi Ulang Berdasarkan Permenkes No. 492 Tahun 2010. Jurnal Kesehatan Masyarakat. https://journal.unnes.ac.id/sju/index.php/higeia/article/view/35451

Putra, R. A., & Azizah, R. (2020). Hubungan Higiene Sanitasi Depot dengan Kualitas Bakteriologis Air Minum Isi Ulang. Jurnal Kesehatan Lingkungan, 12(1), 34–41. https://ejournal.unair.ac.id/JKL/article/view/15450

Putri, A. M., & Raharjo, M. (2019). Analisis Risiko Kesehatan Lingkungan Pajanan Bakteri Escherichia coli pada Air Minum Isi Ulang di Kelurahan Bandarharjo. Jurnal Kesehatan Masyarakat (Undip), 7(4), 481–488. https://ejournal3.undip.ac.id/index.php/jkm/article/view/24467

Putri, I., & Priyono, B. (2022). Analisis bakteri coliform pada air minum isi ulang di Kecamatan Gajahmungkur. Life Science, 11(1), 89–98. https://doi.org/10.15294/lifesci.v11i1.59799

Rahayu, L., Handayuni, L., Barlian, E., & Yuniarti, E. (2024). Microbiological quality analysis of refill drinking water depots in Padang City. Jurnal Kesehatan Cendikia Jenius, 2(1), 72–77. https://doi.org/10.70920/jenius.v2i1.110

Rahman, A., dkk. (2022). Faktor-faktor yang Berhubungan dengan Kualitas Mikrobiologi Air Minum pada Depot Air Minum Isi Ulang. Jurnal Kesehatan Masyarakat. https://ejournal.uniska-bjm.ac.id/index.php/JKM/article/view/7245

Rahmi, A., Irdawati, & Rosita, A. (2025). Analisis kandungan Escherichia coli dan Coliform pada air minum isi ulang depot air minum daerah Kabupaten Solok. Prosiding Seminar Nasional Biologi, 4(2), 1065–1072. https://doi.org/10.24036/prosemnasbio/vol4/1090

Raksanagara, A. S., Fitriyah, S., Afriandi, I., Iskandar, H., & Sari, S. Y. I. (2018). Aspek Internal dan Eksternal Kualitas Produksi Depot Air Minum Isi Ulang: Studi Kualitatif di Kota Bandung. Majalah Kedokteran Bandung, 50(1), 53–60.https://doi.org/10.15395/mkb.v50n1.1143

Rezkina, K., & Roslina, A. (2024). Perbandingan pertumbuhan Escherichia coli dan Salmonella sp. pada hari pertama dan hari kedua di depot air minum isi ulang. Jurnal Kedokteran dan Kesehatan: Publikasi Ilmiah Fakultas Kedokteran Universitas Sriwijaya, 11(1), 22–31. https://doi.org/10.32539/jkk.v11i1.225

Riyanti, R., Putri, D. H., Erlinda, & Yuniarti, E. (2022). Deteksi bakteri E. coli dan Coliform dengan metode CFU pada uji kualitas air bersih. Prosiding Seminar Nasional Biologi, 1(2), 925–934. https://doi.org/10.24036/prosemnasbio/vol1/222

Saraswati, H., dkk. (2021). Analisis Mikrobiologi Air Minum Isi Ulang pada Depot Air Minum di Wilayah Kerja Puskesmas. Jurnal Kesehatan Masyarakat (Undip), 9(3), 324–330. https://ejournal3.undip.ac.id/index.php/jkm/article/view/29596

Sari, M. P., & Wahyuni, S. (2022). Perbandingan Efektivitas Metode Uji Kualitas Air Minum. Jurnal Sains dan Kesehatan. https://jsk.farmasi.unmul.ac.id/index.php/jsk

Savitri, L., Nur Kholis, M. A., Prasetyawan, F., Saristiana, Y., Amanda, C., & Mebung, K. K. (2025). Assessment of Escherichia coli contamination in drinking water from refill depots. Biology, Medicine, & Natural Product Chemistry, 14(1), 443–446. https://doi.org/10.14421/biomedich.2025.141.443-446

Suryani, D. (2020). Hubungan Higiene Sanitasi dengan Kualitas Bakteriologis Depot Air Minum Isi Ulang (DAMIU) di Kota Yogyakarta. Jurnal Kesehatan Masyarakat. http://eprints.uad.ac.id/21443/

Wandari, A., dkk. (2022). Identifikasi Bakteri Escherichia coli pada Air Minum Isi Ulang di Depot Air Minum. Jurnal Biologi dan Pembelajarannya (JB&P), 9(1), 11–17. https://ojs.iptp.or.id/index.php/jbp/article/view/364

Widyarto, A., dkk. (2019). Higiene sanitasi dan kualitas bakteriologis depot air minum isi ulang (DAMIU). HIGEIA (Journal of Public Health Research and Development), 3(3),455–466. https://journal.unnes.ac.id/sju/index.php/higeia/article/view/30351

Wijaya, A. (2021). Analisis Teknis Efektivitas UV Sterilizer dalam Menurunkan Kadar Bakteri Total Coliform. Jurnal Inovasi Teknologi Lingkungan. https://jurnalteknologi.ubb.ac.id/index.php/jt/article/view/215

Yunada, T. F., Rahayu, W. P., & Herawati, D. (2023). Keamanan mikrobiologis air minum isi ulang dan perubahannya selama penyimpanan. Jurnal Ilmu Pertanian Indonesia, 28(4), 581–590. https://doi.org/10.18343/jipi.28.4.581

Zulfa, N., & Mulyawaty, I. (2023). Higiene sanitasi dan uji pemeriksaan mikrobiologi depot air minum isi ulang. HIGEIA (Journal of Public Health Research and Development), 7(1), 44–54. https://doi.org/10.15294/higeia.v7i1.61441

Author Biographies

Muthii’ah Zahra, Department of Biology, Faculty of Mathematics and Natural Sciences, Universitas Negeri PadangJl. Prof. Dr. Hamka, Padang, West Sumatra 25171, Indonesia

Author Origin : Indonesia

Elsa Yuniarti, Universitas Negeri Padang

Author Origin : Indonesia

Fitria Fitria, UPTD. Laboratorium Lingkungan Dinas Perumahan Rakyat Kawasan Pemukiman dan Lingkungan Hidup

Author Origin : Indonesia

Downloads

Download data is not yet available.

How to Cite

Zahra, M., Yuniarti, E., & Fitria, F. (2026). Microbiological Analysis of Escherichia coli in Refilled Drinking Water in Pariaman City. Jurnal Biologi Tropis, 26(4), 1312–1321. https://doi.org/10.29303/jbt.v26i4.12397