A Development of a Coarse Particle Concentration Measurement System Using a Crystal-Based Sensor and a Dust Sensor for Air Quality Measurement

Penulis

Arif Budianto , Susi Rahayu , Laili Mardiana , Ramadian Ridho Illahi , Rosita Juniarti

DOI:

10.29303/jpft.v10i`1.6692

Diterbitkan:

2024-06-02

Terbitan:

Vol 10 No `1 (2024): January-June (In Press)

Kata Kunci:

Coarse Particle, Dust Sensor, Frequency, Oscillator, Sensor System

Articles

Cara Mengutip

Budianto, A., Rahayu, S., Mardiana, L., Ridho Illahi, R., & Juniarti, R. (2024). A Development of a Coarse Particle Concentration Measurement System Using a Crystal-Based Sensor and a Dust Sensor for Air Quality Measurement. Jurnal Pendidikan Fisika Dan Teknologi (JPFT), 10(`1), 10–15. https://doi.org/10.29303/jpft.v10i`1.6692

Unduhan

Data unduhan belum tersedia.

Metrik

Metrik sedang dimuat ...

Abstrak

QCM or quartz crystal microbalance is a non static crystal that can be used as a mass sensor. As a piezoelectric crystal, a QCM generates an electrical signal with a specific frequency. The frequency change can be utilized as a frequency counter in a mass measurement system. This study aims to develop a coarse particle sensor system using a QCM and an oscillator circuit. In line with this, this study uses an oscillator circuit and a QCM for a sensor development. Thus, the frequency measurement of the QCM contains an oscillator and a signal conditioner connected to a microcontroller. For this purpose, an Arduino Nano was used as the signal processing, while a QCM was used as a coarse particle sensor and compared to a digital dust sensor (Winsen ZH03). The sensor system was evaluated using a fixed-type crystal connected to an oscillator: 2.5 MHz - 7.2 MHz. Arduino Nano processed the frequency signal generated by the developed oscillator. The results show that the sensor system has a stable output signal compared to the comparator. There is a linear correlation between the frequency measured by the system and the oscilloscope (99.73%). It can be concluded that the sensor system can measure coarse particle concentrations from 32-620 ug/cm3 (frequencies from 2 MHz to 7.2 MHz) with a response time of 1 second. The system has an accuracy of 99% and a resolution of 1 Hz.

Referensi

Barański, R., Galewski, M. A., & Nitkiewicz, S. (2019). The Study of Arduino Uno Feasibility for DAQ Purposes. Diagnostyka, 20(2), 33–48. https://doi. org/10.29354/diag/109174.

Budianto, A., Ponco Wardoyo, A. Y., Masruroh, Dharmawan, H. A., & Nurhuda, M. (2020). A Study of the Correlation Between Fine Particle Mass Loading Effect and Frequency Shift of a Bare QCM. AIP Conference Proceedings, 2296(November). https://doi.org/10.1063/5.0030820.

Budianto, A., Wardoyo, A. Y. P., Masruroh, M., Dharmawan, H. A., & Nurhuda, M. (2021). Performance Test of an Aerosol Concentration Measurement System Based on Quartz Crystal Microbalance. Journal of Physics: Conference Series, 1811, 1–8. https://doi.org/10.1088/1742-6596/1811/1/ 012033.

Budianto, A., Wardoyo, A. Y. P., Dharmawan, H. A., Hadi, K. A, & Mardiana, L. (2023). Graphene Oxide-Coated Quartz Crystal Microbalance for Bioparticle Detection (A Case Study for Bacillus sp.). Evergreen, 10(01), 155–161.

Cerda, R. M. (2014). Understanding Quartz Crystals and Oscillators (Unabridge). Norwood: Artech House Publisher.

Cestnik, R., Mau, & Rosenblum, M. (2022). Inferring Oscillator's Phase and Amplitude Response From a Scalar Signal Exploiting Test Stimulation. New Journal of Physics, 24, 123012.

Eeftens, M., Meier, R., Schindler, C., Aguilera, I., Phuleria, H., Ineichen, A., Davey, M., Ducret-stich, R., Keidel, D., Probst-hensch, N., Künzli, N., & Tsai, M. (2016). Development of Land Use Regression Models for Nitrogen Dioxide, Ultrafine Particles, Lung Deposited Surface Area, and Four Other Markers of Particulate Matter Pollution in the Swiss SAPALDIA Regions. Environmental Health, 1–14. https://doi.org/10.1186/s12940-016-0137-9.

Gobato, R. (2019). Rhodochrosite as Crystal Oscillator. American Journal of Biomedical Science & Research, 3(2), 187–187. https://doi.org/10.34297/ajbsr.2019.03.000659.

Lee, K. K., Granhaug, K., & Andersen, N. (2013). A Study of Low-Power Crystal Oscillator Design. Norchip, 1, 4–7. https://doi.org/10.1109/NORCHIP.2013.6702036

Lombardi, M. A. (2002). Fundamentals of Time and Frequency. In The Mechatronics Handbook (pp. 17-1-17–18). https://doi.org/ 10.1201/9781420037241.ch10.

Mardiana, L., Wardoyo, A.Y.P., Masruroh, M., & Dharmawan, H.A. (2020). Identification of the Relationship of Carbon Dioxide Concentration and the Frequency Changes of a Quartz Crystal Microbalance (QCM) Oscillation Sensor as a Preliminary Study of a Carbon Dioxide Gas Sensor. AIP Conference Proceedings, 2296, 020119.

Mardiana, L., Wardoyo, A. Y. P., Masruroh, M., & Dharmawan, H. A. (2023). A Study of an n-TiO2 Coated QCM Sensor’s Response and Reversibility under CO2 Exposure. Polish Journal of Environmental Studies, 32(2), 1735–1742.

Murrieta-Rico, F. N., Sergiyenko, O. Y., Petranovskii, V., Hernandez-Balbuena, D., Lindner, L., Tyrsa, V., Tamayo-Perez, U. J., & Nieto-Hipolito, J. I. (2018). Optimization of Pulse Width for Frequency Measurement by the Method of Rational Approximations Principle. Measurement: Journal of the International Measurement Confederation, 125(April), 463–470. https://doi.org/10. 1016/j.measurement.2018.05.008.

Putri, N. P., Suaebah, E., Rohmawati, L., Santjojo, D. J. D. H., Masruroh, & Sakti, S. P. (2023). Implications of the Electrodeposition Scan Rate on the Morphology of Polyaniline Layer and the Impedance of a QCM Sensor. Trends in Sciences, 20(3). https://doi.org/10.48048/ tis.2023.6411.

Rinaldi, R. G. & Fauzi, A. (2019). A Complete Damped Harmonic Oscillator Using an Arduino and an Excel Spreadsheet. Physics Education, 55, 015024. https://doi.org/10.1088/1361-6552/ab539d.

Sakti, S. (2014). Dual Channel High Precision 26 Bit Frequency Counter Using CPLD XC95108XL for QCM Sensor System. International Journal of Information and Electronics Engineering, 4(3), 239–243. https://doi.org/10.7763/ijiee.2014.v4.441.

Wardoyo, A., & Budianto, A. (2017). A DC Low Electrostatic Filtering System For PM2.5 Motorcycle Emission. IEEE Xplore, 1, 51–54.

Wardoyo, A. Y. P., Dharmawan, H. A., Nurhuda, M., & Budianto, A. (2020). A High Voltage Electrostatic Filter for Particulate Matter PM2.5 Capture Applied in Motor Vehicle Exhaust System. Journal of Physics: Conference Series, 1528(1). https://doi.org/10.1088/1742-6596/1528/ 1/012001.

Wen, H., Xiao, Z., Markham, A., & Trigoni, N. (2015). Accuracy Estimation for Sensor Systems. IEEE Transactions on Mobile Computing, 14(7), 1330–1343. https://doi.org/10.1109/TMC.2014.2352262

Widhowati, A. A., Wardoyo, A. Y. P., Dharmawan, H. A., Nurhuda, M., & Budianto, A. (2021). Development of a Portable Volatile Organic Compounds Concentration Measurement System Using a CCS811 Air Quality Sensor. IEEE Xplore, 1–5. https://doi.org/10.1109/ISESD530 23.202 1.9501642

Wu, J., Yan, Y., Hu, Y., Qian, X., & Zheng, G. (2022). Oscillation Frequency Measurement of Gaseous Diffusion Flames Using Electrostatic Sensing Techniques. Fuel, 311(April 2021), 122605. https://doi.org/10. 1016/j.fuel.2021.122605

Zhou, H., Melloni, L., Poeppel, D., & Ding, N. (2016). Interpretations of Frequency Domain Analyses of Neural Entrainment: Periodicity, Fundamental Frequency, and Harmonics. Hypothesis and Theory, 10(June), 1–8. https://doi.org/ 10.3389/fnhum.2016.00274

Biografi Penulis

Arif Budianto, University of Mataram

Susi Rahayu, University of Mataram

Materials Physics Laboratory, Faculty of Mathematics and Natural Sciences

Laili Mardiana, University of Mataram

Ramadian Ridho Illahi, University of Mataram

Rosita Juniarti, University of Mataram

Lisensi

Hak Cipta (c) 2024 Susi Rahayu, Arif Budianto, Laili Mardiana, Ramadian Ridho Illahi, Rosita Juniarti

Creative Commons License

Artikel ini berlisensiCreative Commons Attribution-ShareAlike 4.0 International License.

Penulis yang menerbitkan Jurnal Pendidikan Fisika dan Teknologi (JPFT) setuju dengan ketentuan sebagai berikut:

  1. Penulis memiliki hak cipta dan memberikan hak jurnal untuk publikasi pertama dengan karya yang dilisensikan secara bersamaan di bawah Lisensi Internasional Creative Commons Attribution-ShareAlike License 4.0 (Lisensi CC-BY-SA). Lisensi ini memungkinkan penulis untuk menggunakan semua artikel, kumpulan data, grafik, dan lampiran dalam aplikasi penambangan data, mesin pencari, situs web, blog, dan platform lain dengan memberikan referensi yang sesuai. Jurnal memungkinkan penulis untuk memegang hak cipta tanpa batasan dan akan mempertahankan hak penerbitan tanpa batasan.
  2. Penulis dapat membuat pengaturan kontrak tambahan yang terpisah untuk distribusi non-eksklusif dari versi jurnal yang diterbitkan dari karya tersebut (misalnya, mempostingnya ke penyimpanan institusional atau menerbitkannya dalam sebuah buku), dengan pengakuan atas publikasi awalnya di Jurnal Pendidikan Fisika dan Teknologi (JPFT).
  3. Penulis diizinkan dan didorong untuk memposting karya mereka secara online (misalnya, di repositori institusional atau di situs web mereka) sebelum dan selama proses pengiriman, karena hal itu dapat mengarah pada pertukaran yang produktif, serta kutipan yang lebih awal dan lebih besar dari karya yang diterbitkan (Lihat The Pengaruh Akses Terbuka).

Artikel Serupa

1 2 3 > >> 

Anda juga bisa Mulai pencarian similarity tingkat lanjut untuk artikel ini.