Vol. 21 No. 4 (2026): in Progress
Open Access
Peer Reviewed

Design and Development of a Wastewater Treatment Plant System for Improved Ammonia Removal at Metro Medika Hospital

Authors

Hairun Anwar , Taufik Abdullah , Azwaruddin Azwaruddin , Hismi Susane

DOI:

10.29303/jpm.v21i4.12267

Published:

2026-07-29

Downloads

Abstract

Hospital wastewater contains various pollutants, including ammonia, which may contaminate receiving water bodies and threaten environmental health if not adequately treated. The existing wastewater treatment plant (WWTP) at Metro Medika Hospital, Mataram, was unable to consistently reduce ammonia concentrations to comply with the regulatory limit of 10 mg/L, with the latest effluent concentration reaching 58.1 mg/L. Therefore, this study aimed to redesign the hospital WWTP to improve ammonia removal through the optimization of an integrated anaerobic-aerobic biological treatment system. A laboratory-scale experimental study was conducted using actual hospital wastewater in a modified treatment system consisting of anaerobic and aerobic biofilters, a bioball reactor, and a disinfection unit. The novelty of this study lies in integrating sequential anaerobic-aerobic biological treatment with a combination of attached-growth biofilter media, including DD-01 media, honeycomb media, bioballs, gravel, silica sand, zeolite, and plastic media, to enhance nitrification performance while maintaining a simple and practical treatment configuration. Data were analyzed using descriptive analysis by comparing influent and effluent ammonia concentrations, while treatment performance was evaluated through ammonia removal efficiency calculations. The redesigned WWTP reduced ammonia concentration from 58.1 mg/L to 10.0 mg/L, corresponding to an ammonia removal efficiency of 82.77%, thereby meeting the applicable wastewater quality standard. These findings demonstrate that the proposed WWTP design offers a feasible approach for improving ammonia removal and a promising strategy to support sustainable hospital wastewater management and regulatory compliance.

Keywords:

Ammonia Removal Hospital Wastewater WWTP Redesign

References

[1] G.Tchobanoglous, F.Burton, H. D.Stensel, M.Abu-Orf, R.Tsuchihashi, and B.Pfrang, Wastewater Engineering: Treatment and Resource Recovey. New York: McGraw-Hill, 2014.

[2] Sri Wahyuningsih and A. M.Gitarama, “AMONIA PADA SISTEM BUDIDAYA IKAN,” J. Ilm. Indones., vol. 5, no. 2, pp. 112–125, 2020, doi: 10.36418/syntax-literate.v5i2.929.

[3] Azwarudin, H.Sholehah, Diano karno, and M.Majdi, “Suitable Technology for a Household Scale Workshop System for The Treatment of Wastewater,” J. Pijar MIPA, vol. 18, no. 3, pp. 430–435, 2023, doi: 10.29303/jpm.v18i3.4927.

[4] N. A.Komarudin, N.Izzati, Y.Yolanda, A.Mawardin, and F.Fahrunnisa, “Monitoring Kualitas Limbah Cair Rumah Sakit dan Impilkasinya terhadap Kualitas Air Sungai Brang Biji, Kabupaten Sumbawa,” J. Teknol. Lingkung. Lahan Basah, vol. 11, no. 2, pp. 531–539, 2023, doi: 10.26418/jtllb.v11i2.67160.

[5] N.Ismillayli, L.Mardiana, R.Kurnianingsih, D.Hermanto, and F.Fahrurazi, “Teknologi Pengelolaan Air Siap Minum Di Desa Jago Kabupaten Lombok Tengah,” J. Pijar Mipa, vol. 12, no. 2, pp. 102–106, 2017, doi: 10.29303/jpm.v12i2.349.

[6] kemenkes, Peraturan Menteri Kesehatan Republik Indonesia Nomor 7 Tahun 2019 tentang Kesehatan Lingkungan Rumah Sakit. Indonesia: Kementerian Kesehatan Republik Indonesia, 2019.

[7] E.Ernawati et al., “Identification of the Implementation of Environmental Sanitation in Settlements in Mataram District, West Nusa Tenggara,” J. Pijar Mipa, vol. 19, no. 6, pp. 974–978, 2024, doi: 10.29303/jpm.v19i6.7574.

[8] N.Nurhidayah, H.Sholehah, N.Nurhidayatullah, M.Mulhidin, and T.Abdullah, “Analysis of Pollutant Sources from Community Health Center Activities in Mataram City,” J. Pijar Mipa, vol. 19, no. 6, pp. 1098–1103, 2024, doi: 10.29303/jpm.v19i6.8003.

[9] D. B.Nugroho, N. C.Elvania, andS. I.Purwaningrum, “Analisis Efektivitas Kinerja Instalasi Pengolahan Air Limbah ( IPAL ) Rumah Sakit X,” Environ. Sci., vol. 9, no. 2, pp. 46–61, 2025.

[10] Anonim, Pedoman Teknis Instalasi Pengolahan Air Limbah dengan Sistem Biofilter Anaerob Aerob, Sanitasi. Jakarta: KEMENTERIAN KESEHATAN RI, 2011.

[11] Permen RI, “Peraturan Menteri Lingkungan Hidup dan Kehutanan Republik Indonesia Nomor 68: Baku Mutu Air Limbah Domestik,” in Peraturan Menteri Lingkungan Hidup dan Kehutanan Republik Indonesia, Jakarta: Kementrian Lingkungan Hidup dan Kehutanan Republik Indonesia, 2016, pp. 10–27.

[12] K.Lin et al., “Advanced Treatment and Disinfection of Hospital Wastewater: Progress, Monitoring Gaps, and Trends,” Water (Switzerland), vol. 18, no. 5, pp. 1–32, 2026, doi: 10.3390/w18050605.

[13] I.Bouabadi, Y.Miyah, M.Benjelloun, M.El-habacha, and J.ElAddouli, “Advanced strategies for the innovative treatment of hospital liquid effluents: A comprehensive review,” Bioresour. Technol. Reports, vol. 28, no. October, p. 101990, 2024, doi: 10.1016/j.biteb.2024.101990.

[14] B. A.Kristiantoro and M.Dewi, “Sistem Instalasi Pengolahan Air Limbah (IPAL) Pada Palang Merah Indonesia (PMI) Kabupaten Kediri,” J. TECNOSCIENZA, vol. 9, no. 1, pp. 175–188, 2024, doi: https://doi.org/10.51158/9s4kmd22.

[15] Yanik Tri Lestari and Erny Ernawati Pua Upa, “Analisis Manajemen Pengelolaan Limbah Medis Di Rumah Sakit TNI AL Samuel J. Moeda Kupang,” J. Pangan Gizi dan Kesehat., vol. 9, no. 1, pp. 990–1001, 2020, doi: 10.51556/ejpazih.v9i1.52.

[16] M. B. W.Pratama, E. O.Hutasoit, and W. S.Budhi, “Desain Ulang Instalasi Pengolahan Limbah Greywater dan Sistem Penyaluran Air Limbah (SPAL) Domestik Pada Rusunawa Gunung Anyar Surabaya,” J. Tek. Sipil dan Lingkung., vol. 8, no. 03, pp. 203–212, 2023, doi: 10.29244/jsil.8.03.203-212.

[17] M.Custodio, W.Cuadrado-Campó, R.Peñaloza, C.Vicuña-Orihuela, E.Torres-Gutiérrez, and E.Orellana, “Treatment of Hospital Wastewater Using Activated Sludge with Extended Aeration,” J. Ecol. Eng., vol. 23, no. 11, pp. 24–32, 2022, doi: 10.12911/22998993/152991.

[18] Y.Zhou, Y.Zhu, J.Zhu, C.Li, and G.Chen, “A Comprehensive Review on Wastewater Nitrogen Removal and Its Recovery Processes,” Int. J. Environ. Res. Public Health, vol. 20, no. 4, 2023, doi: 10.3390/ijerph20043429.

[19] G.Ruiz, D.Jeison, O.Rubilar, G.Ciudad, and R.Chamy, “Nitrification-denitrification via nitrite accumulation for nitrogen removal from wastewaters,” Bioresour. Technol., vol. 97, no. 2, pp. 330–335, 2006, doi: 10.1016/j.biortech.2005.02.018.

[20] E.Arvin and P.Harremoes, “Biofilm Reactor Performance,” Wal. Sci. Tech., vol. 22, no. 112, pp. 171–192, 1990, doi: https://doi.org/10.2166/wst.1990.0145.

[21] F.Udianto, H.Koesmantoro, S.Poerwati, and Sunaryo, “Effectiveness of Wastewater Treatment Plant in Reducing PO₄ and NH₃-N Pollutants at Tk. III Brawijaya Hospital Surabaya,” J. Hig. Sanitasi, vol. 5, no. 1, pp. 23–28, 2025, doi: https://doi.org/10.36568/hisan.v5i1.99.

[22] Panisean Nasoetion, D. A. W.S, M.Saputra, and R. I.Ergantara, “Evaluasi dan Redesign Instalasi Pengolahan Air Limbah (IPAL) RS. Pertamina Bintang Amin Bandar Lampung,” J. Rekayasa, Teknol. Dan Sains, vol. 1, no. 03, pp. 75–86, 2017, doi: https://doi.org/10.33024/jrets.v1i2.1100.

[23] F. P.Putra and A.Masduqi, “Evaluation and Design of Wastewater Management at Indrasari Rengat Hospital for Upgrade Program from Class C to B,” IOP Conf. Ser. Earth Environ. Sci., vol. 506, no. 1, 2020, doi: 10.1088/1755-1315/506/1/012029.

[24] D.Wibowo, I.Wirawan, R.Rosdiana, and I.Ilham, “Perencanaan Instalasi Pengolahan Air Limbah: Studi Kasus Rumah Sakit Kabupaten Bombana, Sulawesi Tenggara,” J. Pendidik. Lingkung. dan Pembang. Berkelanjutan, vol. 22, no. 02, pp. 12–22, 2022, doi: 10.21009/plpb.222.02.

[25] R.Riyanto, M. S.Hakim, I. R. W.Ningrum, and T.Huda, “A novel method for the removal of ammonia in hospital wastewater using flow electrolysis,” Desalin. Water Treat., vol. 248, pp. 217–225, 2022, doi: 10.5004/dwt.2022.28081.

[26] S.Ariani, S.Nasir, and E.Melwita, “Effective Ammonia Removal from Hospital Wastewater by Using a Combination of Filtrations and Bio-Adsorbent from Tea Waste,” Indones. J. Environ. Manag. Sustain., vol. 8, no. 4, pp. 145–153, 2024, doi: 10.26554/ijems.2024.8.4.145-153.

[27] L. N. F.Lestari, S.Nasir, and L. N.Komariah, “Effectiveness of Reducing Ammonia Levels in Hospital Wastewater Using A Combination of Bagasse Bio Adsorbent and Nanofiltration Membrane,” J. IPTEK, vol. 29, no. 1, pp. 37–48, 2025, doi: 10.31284/j.iptek.2025.v29i1.7691.

Author Biographies

Hairun Anwar, Department of Environmental Engineering, Mataram College of Environmental Engineering

Author Origin : Indonesia

Taufik Abdullah, Department of Environmental Engineering, Mataram College of Environmental Engineering

Author Origin : Indonesia

Azwaruddin Azwaruddin, Department of Environmental Engineering, Mataram College of Environmental Engineering

Author Origin : Indonesia

Hismi Susane, Department of Environmental Engineering, Mataram College of Environmental Engineering

Author Origin : Indonesia

Downloads

Download data is not yet available.

How to Cite

Anwar, H., Abdullah, T., Azwaruddin, A., & Susane, H. (2026). Design and Development of a Wastewater Treatment Plant System for Improved Ammonia Removal at Metro Medika Hospital. Jurnal Pijar MIPA, 21(4), 729–735. https://doi.org/10.29303/jpm.v21i4.12267